software:broadcom_poe_control_protocol

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
software:broadcom_poe_control_protocol [2020/11/20 13:03]
svanheule Add set classification enable
software:broadcom_poe_control_protocol [2021/09/05 12:20] (current)
svanheule [Set detection type]
Line 210: Line 210:
 ^ Field ^ Size ^ Description ^ ^ Field ^ Size ^ Description ^
 | port | 1 | Port index number. Use ''7f'' to configure all ports with one command. | | port | 1 | Port index number. Use ''7f'' to configure all ports with one command. |
-| detection_type | 1 | ''00'': No detection \\ ''01'': Legacy \\ ''02'': IEEE 802.3af 4-point detection (default) \\ ''03'': 4-point detection, followed by legacy \\ ''05'': 'Wide range' (Zyxel)|+| detection_type | 1 | ''00'': No detection \\ ''01'': Legacy \\ ''02'': IEEE 802.3af 4-point detection (default) \\ ''03'': IEEE 802.3af 4-point detection, followed by legacy \\ ''04'': IEEE 802.3af 2-point detection (not supported\\ ''05'': IEEE 802.3af 2-point detection, followed by legacy |
  
 ==== Set classification enable ==== ==== Set classification enable ====
Line 219: Line 219:
 ^ Field ^ Size ^ Description ^ ^ Field ^ Size ^ Description ^
 | port | 1 | Port index number | | port | 1 | Port index number |
-enable | 1 | Automatic PD classification \\ ''00'': Disable \\ ''01'': Enable |+classification | 1 | Automatic PD classification \\ ''00'': Disable \\ ''01'': Enable |
  
 ==== Set disconnect type ==== ==== Set disconnect type ====
  • software/broadcom_poe_control_protocol.1605877403.txt.gz
  • Last modified: 2020/11/20 13:03
  • by svanheule