software:broadcom_poe_control_protocol

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
software:broadcom_poe_control_protocol [2020/11/19 18:40]
svanheule [Get extended device config] Document fields from set commands
software:broadcom_poe_control_protocol [2021/09/05 12:20] (current)
svanheule [Set detection type]
Line 49: Line 49:
 | ''0e'' | [[#Set port to PSE output mapping]] || | ''0e'' | [[#Set port to PSE output mapping]] ||
 | ''10'' | [[#Set detection type]] || | ''10'' | [[#Set detection type]] ||
 +| ''11'' | [[#Set classification enable]] ||
 | ''13'' | [[#Set disconnect type]] || | ''13'' | [[#Set disconnect type]] ||
 | ''15'' | [[#Set port power limit type]] || | ''15'' | [[#Set port power limit type]] ||
Line 209: Line 210:
 ^ Field ^ Size ^ Description ^ ^ Field ^ Size ^ Description ^
 | port | 1 | Port index number. Use ''7f'' to configure all ports with one command. | | port | 1 | Port index number. Use ''7f'' to configure all ports with one command. |
-| detection_type | 1 | ''00'': No detection \\ ''01'': Legacy \\ ''02'': IEEE 802.3af 4-point detection (default) \\ ''03'': 4-point detection, followed by legacy \\ ''05'': 'Wide range(Zyxel)|+| detection_type | 1 | ''00'': No detection \\ ''01'': Legacy \\ ''02'': IEEE 802.3af 4-point detection (default) \\ ''03'': IEEE 802.3af 4-point detection, followed by legacy \\ ''04'': IEEE 802.3af 2-point detection (not supported) \\ ''05'': IEEE 802.3af 2-point detection, followed by legacy | 
 + 
 +==== Set classification enable ==== 
 +  * ID: ''11'' 
 +  * Request: ''{ [port] [classification] }'' 
 +  * Reply: ''{ [port] [error] }'' 
 + 
 +^ Field ^ Size ^ Description ^ 
 +| port | 1 | Port index number | 
 +| classification | 1 | Automatic PD classification \\ ''00'': Disable \\ ''01'': Enable |
  
 ==== Set disconnect type ==== ==== Set disconnect type ====
Line 376: Line 386:
 | auto_powerup | 1 | | | auto_powerup | 1 | |
 | detection_type | 1 | Port detection type, see [[#Set detection type]] | | detection_type | 1 | Port detection type, see [[#Set detection type]] |
-| classification_enable | 1 | Enable PD classification |+| classification_enable | 1 | Enable PD classification, see [[#Set classification enable]] |
 | disconnect | 1 | Port disconnect type | | disconnect | 1 | Port disconnect type |
 | pair | 1 | Port power pair, see [[#Set port power pair]] | | pair | 1 | Port power pair, see [[#Set port power pair]] |