software:broadcom_poe_control_protocol [2020/11/18 10:04]
svanheule [Set device power management] rename disconnect
software:broadcom_poe_control_protocol [2020/11/20 14:01]
svanheule [Set classification enable]
Line 49: Line 49:
 | ''0e'' | [[#Set port to PSE output mapping]] || | ''0e'' | [[#Set port to PSE output mapping]] ||
 | ''10'' | [[#Set detection type]] || | ''10'' | [[#Set detection type]] ||
 +| ''11'' | [[#Set classification enable]] ||
 | ''13'' | [[#Set disconnect type]] || | ''13'' | [[#Set disconnect type]] ||
 | ''15'' | [[#Set port power limit type]] || | ''15'' | [[#Set port power limit type]] ||
Line 210: Line 211:
 | port | 1 | Port index number. Use ''7f'' to configure all ports with one command. | | port | 1 | Port index number. Use ''7f'' to configure all ports with one command. |
 | detection_type | 1 | ''00'': No detection \\ ''01'': Legacy \\ ''02'': IEEE 802.3af 4-point detection (default) \\ ''03'': 4-point detection, followed by legacy \\ ''05'': 'Wide range' (Zyxel)| | detection_type | 1 | ''00'': No detection \\ ''01'': Legacy \\ ''02'': IEEE 802.3af 4-point detection (default) \\ ''03'': 4-point detection, followed by legacy \\ ''05'': 'Wide range' (Zyxel)|
 +
 +==== Set classification enable ====
 +  * ID: ''11''
 +  * Request: ''{ [port] [classification] }''
 +  * Reply: ''{ [port] [error] }''
 +
 +^ Field ^ Size ^ Description ^
 +| port | 1 | Port index number |
 +| classification | 1 | Automatic PD classification \\ ''00'': Disable \\ ''01'': Enable |
  
 ==== Set disconnect type ==== ==== Set disconnect type ====
Line 376: Line 386:
 | auto_powerup | 1 | | | auto_powerup | 1 | |
 | detection_type | 1 | Port detection type, see [[#Set detection type]] | | detection_type | 1 | Port detection type, see [[#Set detection type]] |
-| classification_enable | 1 | Enable PD classification |+| classification_enable | 1 | Enable PD classification, see [[#Set classification enable]] |
 | disconnect | 1 | Port disconnect type | | disconnect | 1 | Port disconnect type |
 | pair | 1 | Port power pair, see [[#Set port power pair]] | | pair | 1 | Port power pair, see [[#Set port power pair]] |
Line 455: Line 465:
   * ID: ''2b''   * ID: ''2b''
   * Request: (emtpy)   * Request: (emtpy)
-  * Reply: ''[ext_param_0] [pre_alloc] [powerup_mode] [ext_param_3] [ext_param_4] [ext_param_5] [num_pse] [ext_param_7] [ext_param_8]''+  * Reply: ''[ext_param_0] [pre_alloc] [powerup_mode] [disconnect] [ddflag] [ovlo] [num_pse] [ext_param_7] [ext_param_8]''
  
 ^ Field ^ Size ^ Description ^ ^ Field ^ Size ^ Description ^
-ext_param_0 | 1 | p0 from [[#Set device config]] |+uvlo | 1 | Under-voltage detection threshold, see [[#Set device config]] |
 | pre_alloc | 1 |  | | pre_alloc | 1 |  |
 | powerup_mode | 1 | | | powerup_mode | 1 | |
-ext_param_3 | 1 | Related to power management like pre_alloc, powerup_mode +disconnect | 1 | | 
-ext_param_4 | 1 | b1 from [[#Set device config]] | +ddflag | 1 | See [[#Set device config]] | 
-ext_param_5 | 1 | p2 from [[#Set device config]] |+ovlo | 1 | Over-voltage detection threshold, see [[#Set device config]] |
 | num_pse | 1 | Number of BCM59xxx PSE controllers present in the system | | num_pse | 1 | Number of BCM59xxx PSE controllers present in the system |
 | ext_param_7 | 1 | p3 from [[#Set device config]] | | ext_param_7 | 1 | p3 from [[#Set device config]] |